Configure Haas Ethernet UNC Intermediate Local Share

Haas Ethernet - UNC Intermediate Local Share Configuration

CNC Parameters

You will need to verify all parameters listed below that correspond to your CNC control.  These parameters may not match your particular machine’s control.  Document (phone camera) original settings before making modifications!

On Haas Control


Press Settings.

Cursor to top of screen then navigate to Network settings.

Select Wired Connection.

Wired Network Enabled: ON, then press ENTER.

Obtain Address Automatically: OFF, then press ENTER.

IP Address: Enter in IP Address, then press ENTER.

Subnet Mask: Enter in Subnet Mask, then press ENTER.

Default Gateway:  Enter Gateway, then press ENTER.

DNS Server:  do not enter anything.

Press F4 to save changes.

Network Status should display UP if machine is connected to an active network.


Cursor to Net Share Information.

CNC Network Name:  Hard coded, no changes allowed.

Domain Workgroup name:  do not enter anything.

Remote Net Share Enabled: OFF, do not change.

Remote Server Name:  do not enter anything.

Remote User name:  do not enter anything.

Remote Password:  do not enter anything.

Local Net Share Enabled: ON, then press ENTER.

Local Net Share Security: ON, then press ENTER.

Local User Name: hard coded, cannot change (haas).

Local Password: 123456, press ENTER.

Press F4 to save changes.


FactoryWiz DNC Settings

Basic Communication

1.01- Port Type: UNC_Intermediate

1.05- UNC Path to Device:  \\192.168.192.105\User data      (this is an example ip address used)

1.07- UNC path username: haas

1.08- UNC path password: 123456

1.21- End of block (EOB): LF


Sending Options

2.01- Send Directories: Folders to be searched (allowed) when queuing or requesting files.

2.02- Search Subdirectories: True/False choice

2.03- Send Extensions: File extensions that should be displayed / searched when adding files to queue.

2.71- UNC target folder flush interval: 1 (value in hours)


Receiving Options

3.01- Receive Directories:  Folder where received files from this machine will be stored.

3.16- Auto rename type: when receiving file that exists already, overwrite, rename to .bak, or employ version numbering.


Remote Commands

4.02- Request for file command: GET-

4.04- Prefix to assume for requested files: Prefix will be appended to the beginning of the file name for all requested files.

4.05- Suffix to assume for requested files: Suffix will be appended to the end of the file name for all requested files.

4.33- Remote request file path/name: Filename used to perform file request when placed in UNC_Intermediate folder.





Setting 1.07 and 1.08 were added in Version 17.3.1

Prior to Version 17.3.1, the Intializenet.bat needs to be modified to add machines.

Initializenet.bat sample for Haas control (This file resides in FactoryWiz DNC Server folder.  Password must match the local password shown above for setting 1.08)
Initializenet.bat:
  1. open a command prompt
  2. net use "\\192.168.1.40"/USER:haas 123456
  3. exit
**The IP address shown above is used as an example only.  Use the IP address that corresponds to the machine you want to add.



Additional Notes

Outputting CNC Programs

At the Haas control:

Press LIST PROG.

Cursor down to file.

Press F2 to copy file.

Verify User Data is highlighted, press ENTER

Press ENTER again.

File will be copied to User Data folder.  Once there, FactoryWiz DNC will move file from the User Data folder to the Receive folder configured for the Haas machine.


Inputting CNC Programs

Queue file to be sent at FactoryWiz Client workstation.

File will be copied to the User Data folder on the Haas control.

At the Haas control:

Press LIST PROG.

Cursor up and over to User Data field.

Cursor down to file.

Press F2 to copy file.

Verify Memory is highlighted, press ENTER

Press ENTER again.






    • Related Articles

    • Okuma P100 P200 P300 UNC Configuration

      Okuma Configuration On the Okuma, pressing Control plus Reset (looks like /// on the key) should bring up the start menu for Windows. In the start menu you want to run, then enter "compmgmt.msc" and click ok. There should be a local users and groups ...
    • Haas Configuration

      CNC Parameters Newer Haas Press SETNG to bring up the machine settings. Press right arrow until you get to I/O tab. Press WRITE/ENTER button (lower right corner of panel). Use left and right arrow to toggle between choices for each setting. Press ...
    • Moxa Configuration-Wizard (Wired)

      NPort 51xx Moxa Configuration NPort Windows Driver Manager (WHQL certified) NPort Search Utility Download current Moxa driver and firmware for your device (firmware may be out of date depending on supplier’s shelf life of product). Accessing the GUI ...
    • Moxa Configuration Instructions-Wizard (Wireless)

      W2150A Wireless Moxa Configuration Below are a list of links to the latest drivers and firmware for the W2150A wireless Moxa units. Moxa Firmware Update NPort Windows Driver Manager (WHQL certified) NPort Search Utility Download current Moxa driver ...
    • Brother C00 FTP Configuration

      CNC Configuration Sheet for FTP – Brother C00 You will need to verify all parameters listed below that correspond to your CNC control. Document (Phone camera) original settings before making modifications! CNC Parameters: Press EDIT button. Press ...