Reset Factory Default - Steam Series

Reset Factory Default - Steam Series


Reset Factory Default - Steam X, LP, & EP



Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician.

Resetting to factory default will reset all personal settings. Scroll through the menu settings and record the below information:
  1. Programed Recipes
  2. Brew Group Temperature Settings & Offsets
  3. Flowmeter Offsets
  4. Date & Time
  5. Power Save Schedules
Hard Reset

Step 1:
Scroll to Switch Off.
Press encoder, scroll to YES and select. The screen will show OFF and the time. 

From this menu, press and hold the encoder for 10 seconds to enter the deep menu.
Record following information:
  1. Serial Number
  2. Steam LP: FlowMeterRateG
Scroll to Exit Menu. Press the encoder.

You're now ready to reset the machine. 

Step 2:
Turn OFF the high voltage breaker.
Turn OFF the main power toggle switch.

Turn ON the main power rocket switch while simultaneously pressing down the encoder knob and hot water button until the Group 1 display reads Preset Done.

Release the buttons.

Power cycle machine.

Upon power cycling the machine. Group 1 will briefly prompt the firmware version and a blank serial number.

Step 3:
Re-enter the information. The most important is:
  1. Serial Number
  2. Number of Groups
  3. Brew Temperature Offsets
  4. Flowmeter Offset
    1. Steam LP: FlowMeterRate G




Questions or concerns? Please contact: support@slayerespresso.com


    • Related Articles

    • Hard Reset - Single Group

      Hard Reset, Single Group Step 1: Press circle to enter programming Scroll to Advanced Settings and circle to enter Scroll to menu option Save/Restore settings, press circle to enter Arrow up to Reset Factory Default Press circle, arrow to yes, press ...
    • Slayer Board Wiring - Steam Series

      Control board wiring diagrams for Slayer Steam Series. These schematics can be used for identifying control inputs and for reference when replacing the board. *Steam X board wiring can be referenced by the Steam EP drawing.* Questions identifying a ...
    • Hard Reset, Steam X

      Steam X Hard Reset This hard reset will send the brain back to factory settings. This means it will lose all information such as serial number and offsets. Therefore, before doing this procedure, record serial number, brew offsets and flow meter ...
    • Steam Actuator Adjustment - Steam Series

      Adjusting Steam Actuator - Steam Series Objective: Slayer magnetic steam actuators have two positions: Up is a rinse that should bounce back to the off position. On is a continuous steam actuation. The actuator should index in the center and now ...
    • Error Code Identification - Steam Series

      Steam Line Errors Brew Temp AL1: Group temp probe is interrupted or disconnected. Stops heating group. Check that the thermistor is connected, Molex pins are in place and wires are snug. Brew Temp AL2: Group temp probe has a short circuit. Stops ...