Error Code Identification - Single Group

Error Code Identification - Single Group


Single Group Errors


STEAM FILL:
Fill routine has run for ten minutes without detecting water. Will not allow machine to heat and will turn off the steam heater. Unit will need to be reset and water is detected. Check water feed to machine for flow. Check inlet valve is opening, or no restrictions.

STEAM HEATER:
Machine’s pressure is below 1.0bar and no water detected in steam tank. Machine will turn off the heater. Check water flow to the machine.

BREW HEATER:
Error if the machine detects the brew heater overheating and will turn off the heater. Could be RTD error misreading the temp.

STEAM OVERTEMP:
Machine detects overtemp and turns off steam heater

HTR OFF:
Heater is disabled or turned off due to error.

HTR ERR:
The heater is off and there is an error.

STEAM SENSOR:
Transducer is disconnected or interrupted. Check connections at the board, check Molex pins are in place and wires are snug.

BREW FILL:
Brew tank has attempted to heat and detected low or no water.

BREW OVERTEMP:
Machine detects overtemp and turns off brew heater.

BREW SENSOR:
RTD has an error in the connection or has faulted.

INTERNAL OVERTEMP:
The control board has overtemped.

GENERAL ERROR:
Software errors may enable this message.

Questions or concerns? Please contact: support@slayerespresso.com

    • Related Articles

    • Error Code Identification - Steam Series

      Steam Line Errors Brew Temp AL1: Group temp probe is interrupted or disconnected. Stops heating group. Check that the thermistor is connected, Molex pins are in place and wires are snug. Brew Temp AL2: Group temp probe has a short circuit. Stops ...
    • Single Group Electronics Identification Diagram

      2020 Single Group 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Pump 10. SSR Steam Relay 1 5. Solenoids 11. SSR Steam Relay 2 6. Brew Tank RTD 12. SSR Brew Relay If ...
    • Single Group (Classic) Electronics Identification Diagram

      Single Group Classic Electronics Diagram Slayer Single Groups manufactured before January 2020. 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Solenoids 10. SSR Steam ...
    • Eltek Transducer Retrofit - Single Group Classic

      Slayer Single Group (Classic) transducer retrofit guide Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: Update legacy Single Group machines to current Eltek transducer assembly. ...
    • Error Code Identification - Love Controller

      Love Control Errors Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: The Love Controller on the SLAYER V3 is the PID controller for both the pre-heat (SD1/Out1) and steam tanks ...