Hard Reset - Single Group

Hard Reset - Single Group


Hard Reset, Single Group




Step 1:
  1. Press circle to enter programming 
  2. Scroll to Advanced Settings and circle to enter
  3. Scroll to menu option Save/Restore settings, press circle to enter
  4. Arrow up to Reset Factory Default
  5. Press circle, arrow to yes, press circle
  6. Arrow up to Reset Factory Tuned
  7. Press circle, arrow to yes, press circle
  8. Actuate group paddle to go to main screen.
  9. Unplug machine for 10 seconds
  10. Plug machine back in.

Step 2: 

  1. Press circle to enter programming
  2. Scroll to Advanced Settings
  3. Select menu option Heater Control On/Off
  4. Turn on brew boiler
  5. Turn on steam boiler
  6. Actuate group paddle to go to main menu
  7. Machine should heat up in 20-30 min.

Step 3:

  1. Once machine is heated up, you'll need to set the pump pressure again.
  2. Press circle to enter programming
  3. Scroll to Brew Pump Pressure
  4. Press circle to bracket Pump Percentage
  5. Insert blind portafilter
  6. Turn on full brew
  7. Increase percentage until the bar pressure on the gauge reads 10 bar

Questions or concerns? Please contact: support@slayerespresso.com


    • Related Articles

    • Reset Factory Default - Steam Series

      Reset Factory Default - Steam X, LP, & EP Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Resetting to factory default will reset all personal settings. Scroll through the menu settings and record ...
    • Display Operation - Single Group

      Slayer Single Group Display Operation Objective: Navigate touch operations of LCD display. Parts: 99004-60120 DISPLAY ASSEMBLY, HOME Tools: Pad of your thumb. The operation of the single group display is best described in the video below. Using as ...
    • Hard Reset, Steam X

      Steam X Hard Reset This hard reset will send the brain back to factory settings. This means it will lose all information such as serial number and offsets. Therefore, before doing this procedure, record serial number, brew offsets and flow meter ...
    • Testing No Power, Single Group

      Testing No Power, Single Group Time Needed: 10 Minutes Parts Needed: None Tools Needed: #2 Phillips Screwdriver Multi Meter Circuit Board Reference #1 - Main power - 24v DC from power supply #2 - Relay #3 - Display ribbon cable #4 - Transducer #5 - ...
    • Error Code Identification - Single Group

      Single Group Errors STEAM FILL: Fill routine has run for ten minutes without detecting water. Will not allow machine to heat and will turn off the steam heater. Unit will need to be reset and water is detected. Check water feed to machine for flow. ...